INSTALLATION AND SAFETY INSTRUCTIONS
R
emove center cover (B) by squeezing cover together and pulling out
of tabs (C).
Remove 7/8" diameter wire exit plug and oval mounting knock-outs by
taking a screwdriver and punching out plug and knock-outs from back
s
ide of fixture pan (A).
Do not install on a ceiling that would cause the lift and shift
mechanism to disengage (ie. slope ceiling, drop ceiling etc.)
NOTE: FOR FIXTURES PROVIDED WITH 75°C OR 90°C SUPPLY WIRE
WARNING ONLY: RISK OF FIRE. MOST DWELLINGS BUILT BEFORE 1985
HAVE SUPPLY WIRE RATED 60°C. CONSULT A QUALIFIED ELECTRICIAN
BEFORE INSTALLING.
TABS (C)
7/8" WIRE EXIT
MOUNTING HOLE
BALLAST
CENTER COVER (B)
NOTE: Because of the size of this fixture, we recommend two
people to install this fixture.
FIGURE 1
FIGURE 2
DIFFUSER (D)
FIXTURE PAN (A)
IMPORTANT SAFETY INSTRUCTIONS
Be sure the electricity to the system you are working on is turned off;
either the fuse removed or the circuit breaker set at off.
Use of other manufacturers components will void warranty, listing and
create a potential safety hazard.
If you are unclear as to how to proceed, contact a qualified electrician.
You don’t need special tools to install this fixture.
Be sure to follow the steps in the order given.
Read instructions carefully
In order for this lighting fixture to operate properly the buildings
electrical system must be grounded.
Save these instructions.
ASSEMBLY
STEP 1:
STEP 2:
Installation And Safety
Instruction
HC-1297
092807
Line art shown may not exactly match the fixture enclosed.
However, the installation instructions do apply to this fixture.
Fill In Item Number On Carton And
File This Sheet For Fixture Reference. ITEM#_________